• Mwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHP
  • Mwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHP
  • Mwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHP
  • Mwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHP
  • Mwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHP
  • Mwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHP

Mwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHP

After-sales Service: 1years or 2000hours
Warranty: 1years or 2000hours
Type: Basic Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
TCG2020V16
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Marine
Usage
Common Units, Standby Unit
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Transport Package
20gp
Specification
12300*2350*2550
Trademark
MWW
Origin
Germany
HS Code
8503009090
Production Capacity
50000

Product Description

MWM Gas Engine TCG 2020 V12, V16 / TCG 2020 K

For the Highest Ratings in Ecology and Economy!

  • Output range from 1,000 to 1,560 kWel
  • Best electrical and thermal efficiency in its output class
  • Runs on all gas types: natural gas, biogas, landfill gas, sewage gas, mine gas, etc.
  • Low operating costs
  • TCG 2020 is mainly used for CHP plants in Europe and for biogas worldwide
  • The TCG 2020 V12 in the configuration RW (natural gas) and XW (biogas) is specifically optimized for the 1 MWel capacity range, with even lower operating and maintenance costs
  • TCG 2020 K was especially adapted to non-ISO conditions such as high altitudes or high intake air temperatures in the field of natural gas
  • More than 2000 power generators with approximately 2,800,000 kWel already installed around the globe
CONTACT SALES CLICK HERE

ON THIS PAGE

Description - MWM Gas Engine TCG 2020 / TCG 2020 K
High Reliability - MWM Gas Engine TCG 2020 / TCG 2020 K
Performance Data - MWM Gas Engine TCG 2020 / TCG 2020 K
Specifications and Service Intervals - MWM Gas Engine TCG 2020 / TCG 2020 K
Brochure - MWM Gas Engine TCG 2020

The MWM gas engines of the TCG 2020 series are perfectly geared to the challenges of a dynamic market environment. Our models in the output range of 1,000 - 1,560 kWel meet the high requirements of a broad range of applications and guarantee efficiency, reliability, flexibility and environmental sustainability, together with low lifecycle costs and high profitability.

Description - MWM Gas Engine TCG 2020 /
TCG 2020 K

TCG 2020 - High Profitability Thanks to High Efficiency

  • Improvements of the intake duct and spark plug provide higher efficiency compared to predecessor model
  • Miller valve control times increase genset efficiency

TCG 2020 V12 in the Configuration RW (Natural Gas) and XW (Biogas) - Increased Efficiency and Extended Useful Life in the 1 MWel Capacity Range

  • For all natural gas and biogas applications in countries with 50 Hz networks
  • Longer maintenance intervals for all natural gas applications extend useful life by two years
  • Optimized electrical efficiency of 43 percent (under ISO conditions) for natural gas applications
  • Optimized lubricant management
  • Lower internal consumption through higher mixture cooler temperatures for natural gas applications

TCG 2020 K - Optimized for Isolated Operation and Non-ISO Conditions

  • Load response in only seven steps
  • Fast and reliable supply in the event of grid failures or in isolated operation
  • Special 1,000 kWel variant available for high altitude setup and different intake air temperatures

Higher Efficiency and Lower Pollutant Emissions

  • Smaller dead spaces in combustion chamber ensure more complete combustion
  • Reduced fuel consumption and CO and HC emissions
  • This enables gas savings of up to 15 percent a year and increases the profitability of the plant

Higher Efficiency and Long Maintenance Intervals

  • Effective crankcase ventilation increases efficiency by utilizing the returned combustible blow-by gas
  • Optimized blow-by return and improved separation of the gas phase and liquid phase enable longer maintenance intervals for the turbocharger thanks to the clean intake air

K Editions: Maximum Output at Low Costs

  • Improved output capacity of TCG 2020 K under non-ISO conditions and excellent load response through optimum turbocharger design with broad performance map
  • New turbocharger TCR 16 for TCG 2020 with water-cooled bearing housing eliminates need for separate maintenance stages for the turbocharger

High Reliability - MWM Gas Engine TCG 2020 /
TCG 2020 K

Few Interruptions Due to Long Maintenance Intervals

  • No more than two interruptions a year due to scheduled maintenance
  • Longest interval until major overhaul compared to competitors
  • Use of Xchange components enables time savings of up to 75 percent during the major overhaul, resulting in reduced costs

High Reliability through Mature Drive Technology in 60 Hz Range

  • Engine can be operated with an optimum speed of 1500 RPM.
  • Lower speed ensures stable and complete combustion, resulting in lower CO emissions and less component wear and tear

MWM Gas Engine TCG 2020 V12, V16 / V20 TCG 2020 K

For the Highest Ratings in Ecology and Economy!

  • Output range from 1,000 to 2,000 kWel
  • Best electrical and thermal efficiency in its output class
  • Runs on all gas types: natural gas, biogas, landfill gas, sewage gas, mine gas, etc.
  • Low operating costs
  • TCG 2020 is mainly used for CHP plants in Europe and for biogas worldwide
  • The TCG 2020 V12 in the configuration RW (natural gas) and XW (biogas) is specifically optimized for the 1 MWel capacity range, with even lower operating and maintenance costs
  • TCG 2020 K was especially adapted to non-ISO conditions such as high altitudes or high intake air temperatures in the field of natural gas
  • More than 2000 power generators with approximately 2,800,000 kWel already installed around the globe
CONTACT SALES CLICK HERE

ON THIS PAGE

Description - MWM Gas Engine TCG 2020 / TCG 2020 K
High Reliability - MWM Gas Engine TCG 2020 / TCG 2020 K
Performance Data - MWM Gas Engine TCG 2020 / TCG 2020 K
Specifications and Service Intervals - MWM Gas Engine TCG 2020 / TCG 2020 K
Brochure - MWM Gas Engine TCG 2020

The MWM gas engines of the TCG 2020 series are perfectly geared to the challenges of a dynamic market environment. Our models in the output range of 1,000 - 1,560 kWel meet the high requirements of a broad range of applications and guarantee efficiency, reliability, flexibility and environmental sustainability, together with low lifecycle costs and high profitability.

Description - MWM Gas Engine TCG 2020 /
TCG 2020 K

TCG 2020 - High Profitability Thanks to High Efficiency

  • Improvements of the intake duct and spark plug provide higher efficiency compared to predecessor model
  • Miller valve control times increase genset efficiency

TCG 2020 V12 in the Configuration RW (Natural Gas) and XW (Biogas) - Increased Efficiency and Extended Useful Life in the 1 MWel Capacity Range

  • For all natural gas and biogas applications in countries with 50 Hz networks
  • Longer maintenance intervals for all natural gas applications extend useful life by two years
  • Optimized electrical efficiency of 43 percent (under ISO conditions) for natural gas applications
  • Optimized lubricant management
  • Lower internal consumption through higher mixture cooler temperatures for natural gas applications

TCG 2020 K - Optimized for Isolated Operation and Non-ISO Conditions

  • Load response in only seven steps
  • Fast and reliable supply in the event of grid failures or in isolated operation
  • Special 1,000 kWel variant available for high altitude setup and different intake air temperatures

Higher Efficiency and Lower Pollutant Emissions

  • Smaller dead spaces in combustion chamber ensure more complete combustion
  • Reduced fuel consumption and CO and HC emissions
  • This enables gas savings of up to 15 percent a year and increases the profitability of the plant

Higher Efficiency and Long Maintenance Intervals

  • Effective crankcase ventilation increases efficiency by utilizing the returned combustible blow-by gas
  • Optimized blow-by return and improved separation of the gas phase and liquid phase enable longer maintenance intervals for the turbocharger thanks to the clean intake air

K Editions: Maximum Output at Low Costs

  • Improved output capacity of TCG 2020 K under non-ISO conditions and excellent load response through optimum turbocharger design with broad performance map
  • New turbocharger TCR 16 for TCG 2020 with water-cooled bearing housing eliminates need for separate maintenance stages for the turbocharger

High Reliability - MWM Gas Engine TCG 2020 /
TCG 2020 K

Few Interruptions Due to Long Maintenance Intervals

  • No more than two interruptions a year due to scheduled maintenance
  • Longest interval until major overhaul compared to competitors
  • Use of Xchange components enables time savings of up to 75 percent during the major overhaul, resulting in reduced costs

High Reliability through Mature Drive Technology in 60 Hz Range

  • Engine can be operated with an optimum speed of 1500 RPM.
  • Lower speed ensures stable and complete combustion, resulting in lower CO emissions and less component wear and tear
CONTACT SALES CLICK HERE

Performance Data - MWM Gas Engine TCG 2020 /
TCG 2020 K

Natural gas applications, NOx ≤ 500 mg/Nm3 *

  TCG 2020 V12
RW = Optimized for high total efficiency at requested power
Engine type 50 Hz
Electrical output kW 1000
Thermal output ± 8% kW 1056
Electrical efficiency % 43.0
Thermal efficiency % 45.4
Total efficiency % 88.4
Power to heat ratio ** 0.95
  TCG 2020 V12 K
K = Optimized for robustness and low CAPEX
TCG 2020 V12
R = Optimized for high total efficiency
Engine type 50 Hz 60 Hz 50 Hz 60 Hz
Electrical output kW 1125 1125 1200 1200
Thermal output ± 8% kW 1251 1262 1189 1196
Electrical efficiency % 41.0 40.7 43.7 43.4
Thermal efficiency % 45.6 45.6 43.3 43.2
Total efficiency % 86.6 86.3 87.0 86.6
Power to heat ratio ** 0.90 0.89 1.00 1.00
  TCG 2020 V16 K
K = Optimized for robustness and low CAPEX
TCG 2020 V16
R = Optimized for high total efficiency
Engine type 50 Hz 60 Hz 50 Hz 60 Hz
Electrical output kW 1500 1500 1560 1560
Thermal output ± 8% kW 1675 1686 1576 1589
Electrical efficiency % 40.9 40.6 43.3 43.0
Thermal efficiency % 45.7 45.7 43.8 43.8
Total efficiency % 86.6 86.3 87.1 86.8
Power to heat ratio ** 0.89 0.89 0.99 0.98

* With 5% O2 and dry exhaust gas
** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
 
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.

Biogas, Landfill Gas, and Sewage Gas Applications, NOx ≤ 500 mg/Nm3 *

  TCG 2020 V12
XW = Optimized for operation with biogases at requested power
TCG 2020 V12
X = Optimized for operation with biogases
Engine type 50 Hz 50 Hz 60 Hz
Electrical output kW 1000 1200 1200
Thermal output ± 8% kW 1035 1192 1201
Electrical efficiency % 42.6 43.0 42.7
Thermal efficiency % 44.1 42.7 42.7
Total efficiency % 86.7 85.7 85.4
Power to heat ratio ** 0.97 1.00 1.00
  TCG 2020 V16
X = Optimized for operation with biogases
Engine type 50 Hz 60 Hz
Electrical output kW 1560 1560
Thermal output ± 8% kW 1566 1580
Electrical efficiency % 42.7 42.3
Thermal efficiency % 42.9 42.8
Total efficiency % 85.6 85.1
Power to heat ratio ** 1.00 0.99

* With 5% O2 and dry exhaust gas
** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
 
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.

Specifications and Service Intervals -
MWM Gas Engine TCG 2020 / TCG 2020 K

Dimensions and Weights

  TCG 2020 V12
RW = Optimized for high total efficiency at requested power
XW = Optimized for operation with biogases at requested power
Engine type 50 Hz
Length mm 4660
Width mm 1810
Height mm 2210
Dry weight genset kg 11200
Bore / stroke mm 170/195
Displacement dm3 53.1
Speed min-1 1500
Mean piston speed m/s 9.8
  TCG 2020 V12 K
K = Optimized for robustness and low CAPEX
TCG 2020 V12
R = Optimized for high total efficiency
X = Optimized for operation with biogases
Engine type 50 Hz 60 Hz 50 Hz 60 Hz
Length mm 4790 5970 4790 5970
Width mm 1810 1790 1810 1790
Height mm 2210 2210 2210 2210
Dry weight genset kg 11700 13000 11700 13000
Bore / stroke mm 170/195 170/195 170/195 170/195
Displacement dm3 53.1 53.1 53.1 53.1
Speed min-1 1500 1500 1500 1500
Mean piston speed m/s 9.8 9.8 9.8 9.8
  TCG 2020 V16 K
K = Optimized for robustness and low CAPEX
TCG 2020 V16
R = Optimized for high total efficiency
X = Optimized for operation with biogases
Engine type 50 Hz 60 Hz 50 Hz 60 Hz
Length mm 5430 6640 5430 6640
Width mm 1810 1790 1810 1790
Height mm 2210 2210 2210 2210
Dry weight genset kg 13300 14900 13300 14900
Bore / stroke mm 170/195 170/195 170/195 170/195
Displacement dm3 70.8 70.8 70.8 70.8
Speed min-1 1500 1500 1500 1500
Mean piston speed m/s 9.8 9.8 9.8 9.8

The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.

Service Intervals

TCG 2020 V12, V16, V12 K, V16 First service (check valve clearance) Cylinder head inspection Major overhaul
Natural gas, purified biogas, sewage gas, and landfill gas 4000 oh 32000 oh* 64000 oh
Unpurified biogas, sewage gas, and landfill gas 2000 oh 16000 oh* 64000 oh
TCG 2020 V12
RW = Optimized for high total efficiency at requested power
XW = Optimized for operation with biogases at requested power
First service (check valve clearance) Cylinder head inspection Major overhaul
Natural gas 4000 oh 40000 oh* 80000 oh
Purified biogas, sewage gas, and landfill gas 4000 oh 32000 oh* 64000 oh
Unpurified biogas, sewage gas, and landfill gas 2000 oh 16000 oh* 64000 oh

* "at the latest"
 
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.

Mwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHPMwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHPMwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHPMwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHPMwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHPMwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHPMwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHPMwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHPMwm Tcg2020V16 Tcg2020 V16 1.56MW Gas Generator with CHP

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now